Sr. No. | Image of Equipment | Name of the Equipment | Brief Description (key feature) of each Equipment | Name of Faculty In-charge of the equipment | Location | Purchased from Institute fund/ Project grant/ others | Status of Equipment (Working/Not Working) |
---|---|---|---|---|---|---|---|
41 | Microwave Integrated Circuit/PCB Prototype (LPKF Protomat S103) | Microwave Integrated Circuit/PCB Prototype (LPKF Protomat S103) | Fully automated operation with highestresolution (0.5µm) and repe-atability (±0.001 mm). Suitable for multilayer and RF (FR4 18/18 Cu) material. Can achieve PCB track widths up to 100µm. 2.5 dimensional operation with Z axis control. Automatic 15 position tool changer; automatic milling width adjustment. Pneumatic non-contact working depth limiter, |
Dr. Arun Kumar Singh | Semiconductor Research Centre | Institute Fund | Working |
42 | Spin Coater (Navson NT12000) | Spin Coater (Navson NT12000) | Maximum rotational speed 12000 rpm. |
Dr. Arun Kumar Singh | Semiconductor Research Centre | DST-FIST | Working |
43 | Wet Benches/ Fume Hoods | Wet Benches/ Fume Hoods | Equipped with HEPA filter and sash to protect from chemical fumes and splashes For wet chemical processing for cleaning, etching etc. Utilities include Nitrogen (N2), Compressed dry air CDA), Deionized water (DI) Comprises of supporting equipments like ultrasonic cleaner, hot plates, magnetic stirrer | Dr. Arun Kumar Singh | Semiconductor Research Centre | Institute Fund | Working |
44 | Probe Station (Ecopia EPS300) | Probe Station (Ecopia EPS300) | Stereo-zoom microscope with adjustable Eyepiece 20X (pair) with 13X-90X and zoom optics 0.67X -4.5X. Low noise shield 4 inch chuck with substrate vacuum Six manipulators with Magnetic bases capable of moving X, Y, and Z direction |
Dr. Arun Kumar Singh |
Semiconductor Research Centre | DST-SERB Project | Working |
45 | Source Measure Unit (SMU) (Keysight B2902A) | Source Measure Unit (SMU) (Keysight B2902A) | Dual channel with capability to source and measure both voltage and current Minimum sourceresolution: 1 pA /1 μV, minimum measurement resolution: 100 fA/100 nV Maximum output: 210 V, 3 A DC/10.5 A pulse Arbitrary waveform generation and digitizing capabilities from 20 μs interval |
Dr. Arun Kumar | Semiconductor Research Centre | Institute Fund | Working |
46 | Vector Network Analyzer (VNA) (Keysight PXIe M9374A) | Vector Network Analyzer (VNA) (Keysight PXIe M9374A) | Frequency Range: 500kHz (or Less) to 20 GHz with resolution of 6 Hz or Less Output Power & Power Sweep Range: -40dBm to + 6dBm upto 20GHz Number of Ports / independent source: 02 | Dr. Arun Kumar | Semiconductor Research Centre | DST-SERB Project | Working |
47 | Spectrum Analyzer (Anritsu MS2720T) | Spectrum Analyzer (Anritsu MS2720T) | Frequency up to 20 GHz Can measure occupied bandwidth, channel power, ACPR, C/I, field strength etc. |
Dr. Arun Kumar Singh | Semiconductor Research Centre | Institute Fund | Working |
48 | Impedance Analyzer (Keysight) | Impedance Analyzer (Keysight) | Frequency up to 20 MHz with 1 mHz resolution. Can measure Impedance(Z), Phase angle, Capacitance, Dissipation Factor (D), Inductance(L), Quality factor (Q), Resistance(R), Conductance(G), Reactance (X), Susceptance (G), Admittance(Y) |
Dr. Arun Kumar Singh |
Semiconductor Research Centre | DST-SERB Project | Working |
49 | Digital Precision Multi-meter (Keysight 34401A) | Digital Precision Multi-meter (Keysight 34401A) | 6½ digit resolution 10 measurement functions: DC/AC voltage, DC/AC current, 2- and 4-wire resistance, diode, continuity, frequency, period Basic accuracy: 0.0035% DC, 0.06% AC 1000 V max voltage input, 3 A max current input | Dr. Arun Kumar Singh | Semiconductor Research Centre | Institute Fund | Working |
50 | DC Power supply (Keysight E3632A) | DC Power supply (Keysight E3632A) | Single and triple output capability DC output range: 0 to 15 V/7 A or 0 to 30 V/4 A With user settable overvoltage and overcurrent protection |
Dr. Arun Kumar Singh | Semiconductor Research Centre | Institute Fund | Working |